Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | PROPERTY VACANT AND SECURED. JOHN AND HIS ITEM ARE OFF PROPERTY. OWNER UNDERSTAND SHE WILL NEED A MIN. HOUSING INSPECTION PRIOR TO REOCCUPING. | |
| 09/19/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | INSPECTION FOLLOW UP SHOW PROPERTY VACANT AND SECURED. GATES LOCKED, NOTICE POSTED ON GATE AND DOOR. NO ACTIVITY ON PROPERTY AT THIS TIME. | |
| 08/17/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | SERVICE PANEL AMR3-31244 50 AMP SERVICE DOUBLE LUGGING ON GROUND TO FEED SUBPANEL. POSSIBLE 220 DRYER ALL CURCUITS 50 AMPS. BOARD THAT PANEL IS MOUNTED TO IS DETERIOATED AND WEATHERED. GROUNDING FOR 1 SUBPANEL DISCONNECTED. WIRING FROM PANEL TO TRAILER UNPROTECTED HANGING. ADDED CURCUIT FOR LIGHTING OUTSIDE UNPROTECTED. FRAYED NOT G.F.CI PROTECTED. LACKING FACE PLATE AND BOX. PORCH: UNDER 7' WITH CURCUITS FOR CEILING FAN. INTERIOR: LIVING CEILING RUSTED, DUCT WORK WITH HOT ROMEX EXPOSED, CEILING NEEDS TO BE REPLACED. HASP LOCK ON DOOR, DOOR JAMB BROKEN, NEEDS REPLACEMENT. BEDROOM EGRES WINDOW BLOCKED ON OUTSIDE, WINDOW DOES NOT OPEN. 2 WINDOW MOUNT A.C IN LIVING ROOM. 1 WINDOW MOUNT A.C IN KITCHEN. EXTENSION CORD THROUGHOUT KITCHEN, LAUNDRY ROOM. VENT LACKING ONGROUND. SUBPANEL: 30,40,60,20 ALL DOUBLE LUGGED. LOOSE WIRES ON BREAKERS. DIFFERENT STYLES OF BREAKERS EXPOSED SUGGLE CONDUCTORS. #2 COPPER HOOD RATED AT 125. MIDWEST BOX HAS 30 AMP CORD RATING. KITCHEN OUTLET SHOW NO EQUIPMENT GROUNDING. OPEN GROUNDING. OPEN GROUNDS THROUGHOUT M.H. MULTIPLE SPLICING THROUGHOUT M.H. SUBPANEL: DOUBLE LUG NEUTRAL, DOUBLE LUGGING FROM PANEL TO SUBPANEL OVERFUSING ON 60 AMP. 2 POLE 30 HAS 15 AMP WIRING, EXTERNAL GROUND RUNNING FROM ROMEX. KNOCK IMPROPER. ALL WORK TO SUBPANEL NOT PERMITTED. COLOR FOR UNGROUNDED CONDUCTOR IMPROPER. OVERFUSING SUBFENDER. KNOCKOUT SEALS MISSING. EMT CONDUCTOR BEING USED IS ROMEX CONNECTOR. NO PHYSICAL PROPTECTION FOR FEEDER. BRANCH CURCUIT WIRING EXPOSED AND UNPROTECTED. IMPROPER CLEARANCE FRONT OF SUBPANEL. DWELLING LACKING SMOKE DETECTORS. SINGLE PANEL IN LIVING ROOM. NO DEAD FRONT PLATE. 50 AMP BREAKER FEED 30 AMP LIFE LINE UNDER M.H (FIRE HAZ.) DOUBLE LUGGING ON BREAKER. EXTENSION CORD IN SONSEALED PLACES. DWELLING LACKING HOT WATER HEATER AND FURNACE. OVERFUSING OF OPEN FENDER CONDUCTOR UNDER M.H (FIRE HAZ.) OPEN SPACES THROUGHOUT STRUCTURE, OPEN CONDUCTOR BRAIDING AGAINST SHARP METALIC SERVICES. |