Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T05DV00178

Parcel: 118220040


Addresses:

235 W 22ND ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
01/19/2007 INSP - INITIAL CODE ENFORCMENT Approved SEE SIRE TO VIEW NOTES/NOV.
03/11/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, MADE CONTACT WITH TENANT FROM APT. #3, UPON ARRIVING AT PROPERTY IT WAS NOTICE THAT EXTERIOR DRAIN FOR KITCHEN IS LEAKING, POSSIBLE GRAY WATER. A CHANEL HAS BEEN MADE TO REMOVE WATER OFF PROPERTY TOWARD STREET & IS BEING ALLOWED TO PUDDLE IN DRIVEWAY. DRAIN PIPE IS OPEN AT TOP OF VENT PIPE. WILL ISSUE 24 HR. N.O.V. FOR 235 B ADDRESS, LICENSED PLUMBER WILL BE REQUIRED.
235 C ADDRESS - TENANT STATED REPAIR TO WATER SUPPLY LINE WERE DONE BY OWNER. OWNER HAD APPROX. 100 FEET DUG UP & INSTALLED NEW LINE. TENANT WILLING TO SIGN AFFIDAVIT STATE 50.
FIRE SAFETY:
(1) NO WORKING SMOKE DETECTOR WERE FOUND, 2-EXIST 1-IN HALLWAY, 1-IN BEDROOM.
EXTERIOR SURFACES:
(1) WOOD WINDOW FRAME SHOW LARGE AMOUNTS OF TERMITE DAMAGE & LACK PAINT PROTECTION, WOOD IS EXPOSED TO THE ELEMENTS.
W//O/P:
CHECK FOR CONVERTED GARAGE TO LIVING SPACE.
MECHANICAL SYSTEM:
(1) FURNACE CLOSET FULL OF LINT & DUST, LARGE AMOUNTS OF MATCHES WERE FOUND IN BURNER COMPARTMENT. ASKED TENANT IF SHE WAS HAVING PROBLEM WITH FURNACE, SHE STATED PIOLET LIGHT KEPT GOING OUT WHEN WINDY CONDITION EXISTED.
INTERIOR FEATURES:
(1) BATHROOM WALL HAS LARGE AMOUNT OF POSSIBLE MOLD & OR MILDEW, WALLS ARE TURNING BLACK.
(2) SOUTHEAST BEDROOM CEILING IN A BADLY DETERIORATED STATE DUE TO ROOF LEAK, DRYWALL HAS BEGAN TO CRUMBLE & TAPPED JOINTS ARE COMING APART.
WEATHER PROOFING:
(1) OLD TRESHOLD MADE OF CONCRETE HAS CRACK & NO LONGER SEALS BOTTOM OF DOOR, LARGE GAP AT BOTTOM OF DOOR.
PLUMBING:
(1) WASHING MACHINE WATER SUPPLY LINES ARE BROKEN. TENANT HAS PLACED WASHING MACHINE OUTSIDE & HAS MADE A HOLE IN DRAIN TO ALLOW MACHINE TO DRAIN INTO ABS PIPE.
(2) APPEARS REPLACEMENT BY OWNER OF UNDERGROUND WATER SUPPLY LINE TO UNIT HAVE BROKEN & HAS ALLOWED WATER TO PUDDLE, STANDING WATER IS APPROX. 3'' DEEP & COVER ON AREA OF APPROX. 6 FEET. THIS CONDITION POSES A HEALTH HAZARD TO THE OCCUPANTS & SURROUNDING NEIGHBORS DUE TO BEING AN ATTRACTIVE NUISANCE TO VARIOUS PEST.
ACCESSORAY STRUCTURES:
(1) FENCING IS IN AN ADVANCE STATE OF DISREPAIR, FENCING MATERIAL BETWEEN FRONT PROPERTY & BACK PROPERTY ARE HELD TOGETHER BY WIRE. POLES ARE BENT, TOP RAILS & CAP HAVE COME APART IN SEVERAL SECTIONS.
ELECTRICAL SYS:
(1) EXTERIOR ELECTRICAL DISCONNECT IS IN A DETERIORATED INTO A STATE OF DILAPIDATION, 60 AMP SERVICE IS BREAKING AWAY FROM DECAYED WOOD BASE. MODIFICATION TO FUSE BOX HAVE BEEN MADE, JUMPER WIRE (2) NOT REQUIRED WIERE GAUGE ARE CONNECTING FUSE. GROUND WIRES & NEUTRAL WIRE ARE CONNECTED TO SAME BAR. WIRE FROM WEATHER HEAD TO T.E.P. ARE CONNECTED BY LUGS, APPEARS T.E.P. HAS NOT INSTALLED CAUSING (APPROVED) ? WOOD BASE SHOWS TERMITE DAMAGE.
(2) EXTERIOR LIGHT FIXTURE IS CONNECTED TO EXTENTION CORD AND IS IMPROPER APPLICATION THEN PLUG INTO RECEPTACLE BOX.
(3) 3 PRONG RECEPTACLE WAS TESTED IN FURNACE CLOSET & WAS FOUND WITH OPEN GROUND.