Case: T05DV00148

Parcel: 122183250


Addresses:

3525 E LEE ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/02/2005 INSP - INITIAL CODE ENFORCMENT Approved 2/28/05 VISITED SITE, TOOK PICTURES,TALKED TENANT , VANESSA, WHO STATED THAT SHE HAD TALKED WITH ROGER PUTZI THE PREVIOUS NITE. VANESSA STATED THAT SHE WENT TO ON COURT ON TUESDAY 2/22/05, HAD BEEN EVICTED AND WAS TO BE OUT BY 2/28/05. IN CONVERSATION BETWEEN VANESSA AND MR. PUTZI, AN EXTENSION OF 1 DAY WAS GRANTEDTO VANESSA TO 3/01/05. RESIDENT WAS NOT YET READY TO LEAVE. STILL ALOT OF TRASH AND DEBRIS IN YARD INCLUDING A SMALL CHEVY PICK-UP (WHITE), WITH EXPIRED PLATES (MARCH OF 03), AND A SMALL WHITE DATSUN (NO PLATES).
EXTERIOR FEATURES: A SMALL SHED ON SOUTHWEST SIDE OF LOT LINE FULL OF DEBRIS SETS RIGHT ON FENCE; 2ND SHED (NORTHWEST) ALSO ON FENCE LINE.SOUTHWEST END OF STRUCTURE HAS SEVERAL EXTENSION CORDS, ONE TIED INTO EXTERIOR LITE FIXTURE GOING INTO STRUCTURE, 2ND CORD COMING OUT OF FIXTURE AND LAYING ON GROUND.STRUCTURE HAS TWO METERS ON SITE, 3525 LEE #1, HAS EXTRA WIRE IN BOX CONNECTED AT THIS TIME ( IF IT DOES CONNECT TO ABOVE BOX IT IS DBL LUGGED). TOP BOX ,3525 LEE #2, HAS SAME WIRE AND IT IS DBL LUGGED.HOTWATER HEATER TANK #1 LACKING PROPER EMERGENCY SHUT-OFF, FLUE PIPE CONNECTIONS LACK PROPER SEALING, AND FLUE PIPE DOES NOT EXTEND 3' ABOVE ROOF LINE.GAS PIPE VALVE TO HEATER NOT AGA APPROVED.ELECTRICAL CORD TO COOLER HAS GROUND PLUG BROKEN OFF.WATER BOND TO UNIT TWO BROKEN OFF.FLUE PIPE TO HOTWATER HEATER(#2) DOES NOT EXTEND 3' ABOVE ROOF LINE.UNIT #2 (NEED RESEARCH FOR POSSIBLE ADDITION), HAS DETERIORATING WOOD SIDING AND ROOF SHEATHING. PRV VALVE ON HOTWATER HEATER INSTALLED INCORRECTLY. NUMBER 2 ELECTRICAL PANEL HAS INCORRECT FRONT DEAD PANEL AND 1-20 AMP BREAKER HAS A 14 GUAGE WIRE CONNECTED TO IT.WOOD ON SOUTHSIDE OF ADDITION IS DETERIORATING.
FRONT
INTERIOR FEATURES: FRONT DOOR LACKS WEATHER PROTECTION. DOOR JAMB NOT SECURED TO WALL. NO SMOKE DETECTOR. KITCHEN WINDOW BROKEN. LITE FIXTURE MISSING IN LIVING ROOM,HAS EXPOSED WIRES. SHOWER TILES MISSING GROUT, TILES FALLING OFF THE WALL AND NOT SEALED. HOT WATER VALVE IN BATH SINK LEAKS CONTINUOSLY. SINK FALLING AWAY FROM WALL , NOT PROPERLY MOUNTED. WOOD AT BATHROOM CEILING SHOWS EVIDENCE OF TERMITE DAMAGE DUE TO ROTTED WOOD. THERE IS A HOLE IN THE LIVINGROOM WALL.
KNOCKED ON DOOR OF UNIT #2, NO ANSWER. LEFT A CARD ON THE FRONT DOOR WITH CONTACT NUMBER, ASKED TENANT TO PLEASE CONTACT D.N.R. INSPECTOR HURD.

NOV TO FOLLOW/ FOLLOW-UP IN 30 DAYS