Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | INSP - FOLLOW UP CODE ENFORCE | Approved | VISITED SITE ON FW/UP COMPLIANCE INSPECTION TO REVIEW STATUS OF UNABATED ITEMS. MET WITH BOTH OWNER & DNR INSP. J. ORTA. FINDINGS ARE AS FOLLOWS: 1) TC 16-11 (C) ELECTRICAL SYS. PERMITS REQUIRED. VIOLATION ABATED - ILLEGALLY INSTALLED JUMPER WIRE W/ 3 PRONG RECEPTACLES HAS BEEN CORRECTED. GFIC RECEPTACLES INSTALLED & MARKED NO EQUIPMENT GROUND PRESENT. VIOLATION ABATED - ILLEGAL INSTALLATION OF ELECTRICAL BREAKER BOX IN BATHROOM HAS BEEN REMOVED & RELOCATED TO EXTERIOR WALL. HOWEVER, NEUTRAL GROUNDS ARE LOCATED IN SAME BAR AS EQUIPMENT GROUNDS. OWNER WILL HAVE CORRECTION MADE BY END OF TODAY. VIOLATION ABATED - WEATHER PROOF COVER INSTALLED FOR WASHING MACHINE RECEPTACLE. 4) TC 16-11 (E) PLUMBING SYSTEM 16-4 PERMITS REQUIRED VIOLATION ABATED - VIOLATION REMOVED. 5) TC 16-11 (D) MECHANICAL EQUIPMENT VIOLATION ABATED - DRIER VENT INSTALLED 11) TC 16-12 BUILDING & STRUCTURES (D) COOLERS VIOLATION ABATED - NEW COOLER INSTALLED. OWNERS HAVE COMPLIED. CLOSE CASE - ALL VIOLATIONS ABATED BY CODE. MARK CASE COMPLIANCE. |
|
| 04/25/2005 | INSP - FOLLOW UP CODE ENFORCE | Approved | 19-A#4 TC-16-11E PLUMBING SYS: UNIT A TOILET HAS BEEN REPAIRED - ABATED. 19-A#4 TC-16-11E PLUMBING: NEW FAUCETS HAVE BEEN INSTALLED, ABATED. 19-A#9 TC-SEC. 16-12 BUILDING EXTERIORS: EXTERIOR PORCH AREA ON EASTSIDE HAS BEEN REPAIRED & REFINISHED, ABATED. 19A-#9 TC SEC. 16-12 BUILD EXTERIOR: WORK HAS BEGAN ON REPAIRING WALLS, PORCH HAS BEEN REMOVED & WORKING ON EXTERIOR WALLS. ABATEMENT NOT COMPLETED. 19-B HEATING: REPAIR TO WALL FURNACE IN UNIT 19-B BEDROOM REPAIRED PRIOR TO USSUING OF N.O.V. HAD BEEN ABATED. OWNER HAS MADE SOME PROGRESS ON ABATEMENT OF ISSUES. WILL SCHEDULE FW/UP INSP. FOR 5/16/05. WENT OVER ISSUES WITH INSP. II RICK SALDATE. EXTENTION WILL DEPEND ON ABATEMENT OF ISSUES DUE ON 5/16/05 INSPT. |