Case: T05DV00030

Parcel: 120071200


Addresses:

17 W LINCOLN ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
11/18/2005 INSP - INITIAL CODE ENFORCMENT Approved CHECKED PROGRESS IN PERMITS PLUS PROGRAM. COMBO PERMITS #T05CM01808 FOR PLUMBING AND ELECTRICAL HAVE BEEN FINALED FOR ADDRESS 15 W LINCOLN ST.
COMBO PERMIT FOR ADDRESS 17 W LINCOLN ST #T05CM01809 HAS ALSO BEEN FINALED. REMAINING PERMIT FOR ADDRESS 19 W LINCOLN ST HAS BEEN INSPECTED AND REQUIRES CORRECTION FOR ELECTRICAL SYSTEM #T05CM01810.
CONTACTED OWNER, OWNER NOT HOME. SPOKE WITH DAUGHTER, LEFT MESSAGE REQUESTING STATUS OF REMAINING VIOLATIONS UNABATED. LEFT CALL NUMBER AND OFFICE NUMBER FOR CONTACT AND REMINDED DAUGHTER PERMITS EXPIRES 12-11-05. OWNERS HAVE MADE GOOD PROGRESS, WILL GRANT 1 MORE EXTENSION FOR 30 DAYS. SCHEDULE ON SITE INSPECTION FOR COMPLAINCE FOR 12-30-05
07/07/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, WALKED PROPERTY TO ACCESS PROGESS ON VIOLATION ISSED BY DNR UINTS 19 A,B,C, HAVE BEEN PAINTED, NEW WINDOW INSTALED (SAME FOR SAME) UINT 19 A HAZARDOUS PORCH STRUCTURE HAS BEEN REMOVED OVER HANG AT EASTSIDE HAS BEEN REPAIRED, PAINTED. NEW ELECTRICAL UP-GRADE FOR 19 A, B, & C HAS BEEN COMPLETED UNIT 19C IS CURRENTLY VACANT & SECURED AT THIS TIME. UNIT 17- EXTERIOR SURFACE HAS BEEN REPAIRED & PAINTED NEW WINDOWS INSTALLED (SAME AS SAME) NEW HOT WATER HEATER ENCLOSURE & PLUMBING HAS BEEN CORRECTED FOR HOT WATER HEATER. VENT STILL LACKING ON EAST SIDE OF UNIT. UNIT 15 C IS CURRENTLY BEING REHAB, NEW HOT WATER HEATER INSTALLED W/ ENCLOSURE, WASH BASIN IN VIOLATION HAS BEEN REMOVED. NEW WINDOWS INSTALLED (SAME FOR SAME)
UNIT 19 B & C DETERIORATED 7 DELAPIDATED PORCH STRUCTURE HAS BEEN REMOVED. MAJORITY OF TERMITE INFESTED WOOD TRIM HAS BEEN REMOVED & REPLACED WITH NEW WOOD TRIM. OWNER MAKING GOOD PROGRESS ABATEMENT IME WILL BE EXTENDED 45 DAYS. PICTURES WERE TAKEN.
01/13/2005 INSP - INITIAL CODE ENFORCMENT Correction Required 17 W LINCOLN ST
PLUMBING
EXTERIOR PLUMBING
1. EXTERIOR SEWER VENT LACKING VENT TUBE OPENED FITTING AT WALL.
2. ALTERATION DONE TO EXTERIOR PLUMBING FOR ABS PIPING
3. TPR DRAIN VALVE LACKING DRAIN PIPE AND WEATHER PROTECTION.
4. LARGE AMOUNT OF COMBUSTABLE VEGETATION CHECK FOR PERMITS.
5. GAS PIPING HAS BEEN MODIFIED FOR GAS STOVE.
EXTERIOR FEATURES
1. WOOD FASCIA IS IN A DETERIORATED SHAPE, WOOD IS CRACKING AND NEEDS WEATHER PROTECTIVE COATING AS WELL AS WINDOW FRAMES.
2. FRONT DOOR - EAST SIDE LACKS DOOR CASING ON TOP.
WEATHER PROTECTION
1. BOTH ENTRY DOORS LACKING WEATHER STRIPPING.
ELECTRICAL SYSTEM NOTE 2 WIRE SYSTEM
1. EXISTING PANEL HAS BEEN ALTERED, ADDITION OF CIRCUITS AND USE OF PLUMBING FIXTURE FOR CONDUIT.
2. PANEL LACKING DEAD PLATE COVER AND IS ABOVE 7'.
3. ELECTRICAL CONDUCTOR NOT IN CONDUIT FOR CEILING LIGHT FIXTURES IN LIVINGROOM AND KITCHEN.
4. 3 PRONG RECEPTACLES INSTALLED THROUGHOUT UNIT AND SOME SHOW REVERSED POLARITY.
5. BATHROOM LIGHT FIXTURES HAVE NON GROUNDED.
FLOORING - INTERIOR FEATURES
1. LAUNDRY ROOM FLOORING IN A DETERIORATED STATED, FLOORING HAS CHIPPED OFF AND CRACKED.