Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/13/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/02/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE TILE ON PORCH ROOF 2) NEED STUCCO AND INSULATION CERTS 3) SEAL A/C COPPER, ELECTRIC LINE EXTERIOR WALL 4) KEEP STUCCO 6" AWAY FROM DIRT 5) INSTALL DRIP LEG GAS PIPING FURNACE AND WATER HEATER 6) WATER HEATER PTR LINE HAS NEGATIVE PITCH 7) ELEVATE AND SECURE DISHWASHER DRAIN LINE TO UNDERSIDE OF COUNTER TOP 8) INSTALL ARC FAULT BEDROOM CIRCUITS 9) STOPPED INSPECTION |
|
| 12/19/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOT READY |