Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM06489
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 6 DT1 NOT COMPLIED WITH AT 48" ON CENTER 2) NO LADDER ACCESS TO ROOF 3) NO PRIOR INSPECTION REPORT FROM 7/3/06 ON SITE |
|
07/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2, 3, 4 AND 6 FROM 5/30/06 NOT DONE 2) ITEM 1 FROM 6/12/06 NOT DONE AT 48" ON CENTER |
|
05/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) 6/DT1 NOT COMPLIED WITH 2) DIAGONAL BRACES REQUIRE 2-16D NAILS 3) RSP4 CLIPS NOT NAILED 4) BIRD BOARDS REQUIRE 3 16D TOE NAILS PER 7/DT1 5) DIAGONAL BRACES MUST BE LET IN AND INSTALLED 6) SHEARWALL CHANNELS NOT PER 3/DT1 7) ROOF MUST BE NAILED PER SD2-NOT STAPLED 8) NO ROOF INSPECTION MADE 9) STOPPED INSPECTION-TOO MANY ITEMS |