Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED CONNECTION FROM TOP PLATE TO TRUSS FRONT AND BACK OF HOUSE 2) FRONT SHEAR 2ND TO 1ST NEEDS TO BE CONTINOUS 3) CLIP OVER WINDOW NORTH SIDE 4) CLIPS ON KING STUD 2ND FLOOR ABOVE HOLDOWNS 5) MISSING HOLDOWNS AT BACK WINDOW 6) OK TO LOAD ROOF |
|
| 05/25/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INCOMPLETE 2) SUPER AND FRAMER TO WALK HOUSES AND CORRECT ALL TO CODE AND OR PLAN |