Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM06469
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/31/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* FILL TUB TO FLOOD LEVEL SECURE WATER LINES AT TUB AND AT REAR HB CALL FOR HCS AND ROUGH INSPECTIONS ALSO. |
|
03/28/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE NOTES FROM PREVIOUS INSPECTION. 2. FILL TUB & SHOWER TO FLOOD LEVEL. |
|
03/22/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* WATER LINES TOUCHING FHA STRAPS AND BANG PLATES PLAN CALLS FOR 3/4" TO REAR HOSE BIB DO YOU HAVE A REVISION FOR 1/2". TRAP ARM FOR LAVATORY IN REAR BATHROOM IS 46" UPC ALLOWS 42" MAXIMUM FOR A 1 1/2 TRAP ARM. USE OF AAV AT KIT SINK REQUIRES PLAN REVISION THERE IS A LOT OF WATER ON FLOOR IS YOUR TEST HOLDING? |