Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06454

Parcel: 10820020A


Addresses:

4088 N 1ST AV #01


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM06454

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/21/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
2. OK TO COVER ALL AREAS
04/20/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP.
2. HORIZONTAL VENTING BELOW THE FLOOD RIM RESTRICTED TO STRUCTURAL CONDITIONS AND ARE TO BE DRAINAGE FITTINGS.
3. TRAP FOR STANDPIPE RECEPTOR TO BE ROUGHED IN NO LESS THAN 6" AFF NOR MORE THAN 18" AFF
STAND PIPE TO BE BETWEEN 18"-30"
4. ALL OVERHEAD PIPE TO BE SUPPORTED.
5. TRAP ARMS TO BE SUPPORTED AS CLOSE TO THE SWEEP AS POSSIBLE.
PLUMBERS TAPE NOT AN APPROVED STRAPPING DO NOT SUPPORT FROM FITTING.
03/23/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO COVER FIRE SEPARATION SUBJ TO TEST