Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/10/2006 PLUMBING - INTERMEDIATE Approved
08/04/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- ALL INTERMEDIATE PIPING HAS BEEN COVERED
- IT IS UNCLEAR IF ANY ISSUES REMAIN SINCE INTERMEDIATE HAS ONLY BEEN PARTIALLY APPROVED.
- RICK MYERS HAS DONE ALL INTERMEDIATE INSPECTIONS ON THIS PROJECT AND HE WILL BE BACK ON MONDAY WHICH IS THE FOLLOWING BUSINESS DAY.

PLEASE CALL FOR 03035 FOR MON. AND RICK CAN COMPLETE YOUR INTERMEDIATE INSPECTION.
05/18/2006 PLUMBING - INTERMEDIATE Partial Approval 1. 2ND FLOOR ABS DWV OK
2. 2ND FLOOR COPPER OK
HOT INSULATED OK
3. BAR SINK REMOVED OK
4. OK TO COVER 2ND FLOOR
05/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. REMOVE "BOOT-LEGGED" BAR SINK ON 2ND FLOOR.
2. 2ND FLOOR PLUMBING NOT READY - NO TEST ON ABS STUB OUT TRAP ARMS. REMOVE JIM CAPS - FOR PERMANENT CAPPING USE SOLVENT WELD CAP.
3. OK TO INSULATE HOT.
05/16/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO INSULATE HOT DOWNSTAIRS - AFTER INSULATION
OK TO COVER DOWNSTAIRS RESTROOMS ONLY.
05/10/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. REDLINES ON SITE - PLAN STILL NEED APPROVAL.
2. REMOVE UPSIDE DOWN TEST WYES
ALL FITTINGS TO OPEN IN THE DIRECTION OF FLOW.
3. USE APPROVED STRAPS
SUPPORT FROM PIPE - NOT FITTINGS.
4. NO TEST ON ABS
05/03/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/21/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. EXISTING PLUMBING IS NOT INSTALLED PER PLAN.
INSTALLED PLUMBING EXCEEDS LIMITATIONS OF PLAN
REVISE PLAN
INCLUDE ALL NEW WORK
CLARIFY EXISTING
04/19/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/17/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ABS DWV UNDERGROUND NOT INSTALLED PER PLAN. NO REDLINES ON SITE.
2. PLEASE EXPOSE ALL PIPE AND FITTINGS FOR INSPECTION.
03/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. REDLINES ON SITE
2. OK TO COVER UNDERGROUND