Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM06426
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2006 | FRAMING | Approved | IVRS - Inspection :* | |
09/15/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRES OBSTRUCTING ATTIC ACCESS-MUST BE 6' AWAY OR PROTECTED 2) INSULATION BAFFLES AROUND ATTIC ACCESS ? 3) REFEE WILL APPLY |
|
09/13/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) UNTIL ATTIC ACCESS IS INSTALLED 2) OK TO INSULATE 3) SHEAR WALLS BLOCKS GARAGE |
|
09/12/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR WALL GARAGE SUPPORT TO BE BLOCKED 2) GARAGE SHEARWALL NEEDS USP RT7 CLIPS PER 10-DT1 3) FIRE STOP KITCHEN 4) PANTRY NEEDS TO BE 2 OSB TOGETHER 5) APEX WITH LINE NEEDS TO BE 12" FROM LIGHT CAN KITCHEN 6) DBL STUD NEEDED UNDER DBL TRUSS DINING ROOM 7) STOPPED INSPECTION STILL NOT READY HAS NOT BEEN WALKED |
|
09/08/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) METAL ELECTRIC BOXES NOT GROUNDED 2) DBL 2 X 4 POST REQUIRED UNDER GARAGE SHORT GIRDER 3) NO DWV WATER TEST 4) M/BR SHEAR 7 REQUIRES ANCHOR BOLTS AT 16" ON CENTER 5) FIRE STOP PORCH CHASE 6) STOPPED INSPECTION-TOO MANY ITEMS |