Permit: T05CM06400

Parcel: 141091100


Addresses:

6664 E WRIGLEY WY


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM06400

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/28/2006 FRAMING Approved IVRS - Inspection :*
07/17/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE TRUSS DRAWING TO CHECK F-3 TRUSS
2) GARAGE TRUSS LAYOUT IS NOT PER APPROVED PLAN. BUILD TO PLAN OR REVISE TO AS BUILT
3) STAIR LANDING IS NOT PER PLAN
4) STAIR PONY WALL MUST SUPPORT 200 POUND FORCE
5) HEADERS MUST BEARON ON TRIMMERS
6) SECOND FLOOR SHEAR WALLS NOT ANCHORED PER PLAN
7) BEARING STUDS AT KITCHEN SINK BORED MORE THAN 40 PERCENT. REPLACE OR ADD STUD SHOES