Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* SEWER RELOCATION IS COMPLETE. WATER LINE WAS REPLACED NEAR METER BUT WAS NOT REPLACED WITH 1 1/4" AS SPECIFIED ON PLAN. |
|
| 05/23/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* I MADE A MISTAKE APPROVING THE YARD WATER LINE -- YOUR PLAN IS CALLING FOR A NEW 1 1/4" PVC WATER LINE. SEWER CONNECTIONS ARE OK TO COVER 1. PROVIDE CLEAN OUT ADAPTER AND IRON BODY CLEANOUT FOR CLEAN OUT IN DRIVEWAY. 2. CLEAN OUTS ARE TO BE MADE WATER AND GAS TIGHT W/APPROVED PIPE THREAD SEALANT. |
|
| 05/12/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/11/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* MIKE 906-2755 REQ AM SEWER TAP OK PIPING OK - MAKE CONNECTION AT PROPERTY LINE ABS TO SDR, INSTALL UPPER TERMINAL CLEANOUT AND CONNECT TO EXISTING CLAY. CAP CLAY IF CONNECTED TO PUBLIC SEWER. PVC WATERLINE. SEC 314.3 PIPING SHALL BE PLACED ON A SOLID SHELF AT ONE SIDE OF THE COMMON TRENCH. INSTALL BLUE TRACER WIRE. T06EX00614 RIGHT OF WAY. |