Permit: T05CM06311

Parcel: 140550620

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
06/12/2006 SHEET ROCK NAILING Approved IVRS - Inspection :*
06/09/2006 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GARAGE CEILING UNDER OCCUPIED SPACE MUST BE FASTENED AT 6" O.C MAXIMUM.
2. LIVING ROOM #1 SHEAR WALL MUST BE NAILED AT TOP PLATE AT 7" OK
3. MBR SHEAR WALLS NAILED IN EXCESS OF 7" OC AND NAILS CANNOT BE WITHIN 3/8" OF EDGES.
4. BR-2 #-3 SHEAR NOT NAILED.
5. M. TOILET TOP PLATE NOT NAILED.
06/08/2006 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED VERIFICATION OF 1025 COMPLETE APPROVAL
2) STOPPED INSPECTION