Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) INSTALL U 410 HGR AT GLUE LAM 2) OK TO DRY IN EXTERIOR |
|
| 04/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL WEB STIFFNERS AT TJI 2) PROVIDE 4 X 4 POST & U410 ? AT GLB |
|
| 03/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 03/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO WRAP 2) PROVIDE CHANGE FOR I JOIST HANGERS 3) ADD RETRO HOLDOWN NEXT TO FRONT DOOR, SOUTH SIDE |
|
| 03/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NAIL OFF 9 SHEER 2" + 12" 10d 2. ADD RETRO H/D FRONT DOOR SOUTH SIDE 3. NAIL OFF 7 SHEER 3" + 12" 4. CS 48" LONG 48" OC 5. NAIL OFF TOP OF SECOND FLOOR INTERIOR SHEER WALL! 6. PROVIDE CHANGE FOR I JOIST FASTENERS AT BEARING WALL. |