Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER ON DIAGONAL 3 1/8" X 12 GLB REQUIRED AT LIVING ROOM HAVE ENGINEER SPECIFY 2) GARAGE SHEARWALL PAHD 2 NOT INSTALLED |
|
| 04/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER AT ROOF GIRDER, BEAMS ROOF HU 410-2900 POUNDS SOUTH & HGU5 26/2 = 4800 NORTH, HANGERS INSTALLED ARE UNDER SIZED 2) LEAK IN 3" ABS GARAGE LID 3) A.B. AT SHEARWALL #7 AT STAIRS 24" ON CENTER 1/2" DIAMETER 4) ALL TRUSSES TO GIRDER & BEAM, UST THA 29 TYP 5) DINING ROOM #6 SHEAR A.B.'S AT 16" ON CENTER 6) BLOCK ALL MECH DUCTS |