Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/15/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |
|
| 05/11/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1, 2, 6, 8, 10 & 11 FROM 5/9/06 NOT DONE |
|
| 05/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 X TRUSS BLOCKING AT GARAGE 8/DT2 2) DWV LEAK 3) FLOOR TRUSS HANGERS MISSING NAILS 4) SEAL SECOND FLOOR PENETRATIONS 5) NAIL 2 X 12 LEDGER TO BEAM 6) LIVING ROOM INSTERIOR BEARING WALL MISSING ANCHOR BOLTS 6' 7) MINIMUM STAIR WIDTH 36" NOT PER CODE 8) NAIL 2ND FLOOR SHEAR WALL BOTTOM PLATES PER PLAN 9) BLOCK DUCT BOOTS 10) MAKE UP AIR INTAKE MUST BE 10FT FROM SEWER VENT 11) 4 X 4 AND 4 X 6 POSTS MISSING EITHER SIDE OF STAIRS |
|
| 05/08/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV TEST 2) FIRE BLOCK CHASES THROUGHOUT 3) DUCT NOT SUPPORTED ON 3 SIDES 4) DRYER VENT DAMAGED |