Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06270

Parcel: 11301146W


Addresses:

3621 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM06270

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/17/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
ADA UPGRADE OK
PLUMBING FINAL OK
OK FOR C OF O S.T.O.I
01/30/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. INTERMEDIATE NOT YET APPROVED
2. REMOVE TOILET FOR CLOSET FLANGE INSPECTION
3. SUPPORT 1/2 CW AND HW AT CHANGE OF DIRECTION
4. ISOLATE 1/2 CW FROM METAL AT WH
5. USE MISSION COUPLING AT TRANSITION FROM CAST IRON TO PLASTIC.
6. FOR FINAL YOU NEED TO INSTALL AN EXPANSION TANK AT WH AND A TEMPERATURE LIMITING DEVICE FOR HW TO LAVITORY.
7. CAULK FIXTURES AND PAINT EXPOSED ABS VENT TERMINATION.