Permit: T05CM06269

Parcel: 10612017R

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/17/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/12/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*PLEASE POST YOUR SUITE NUMBERS
FURNCO COULINGS ARE NOT APPROVED UNDER THE BUILDING . USE SHIELDED COUPLINGS.
1 1/2" TRAP ARM MAY NOT EXCEED THREEE FEET SIX INCHES FROM ?? OF TRAP TO POINT OF VENT.
A TRAP ARM MAY NOT CHANGE SIZE
TRAP AND TRAP ARM TO BE THE SAME SIZE
TRAP MAY BE ONLY ONE PIPE SIZE LARGER THAN THE TAILPIECE . LAVTAIL PIECE-1 1/4"