Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ON TRUSS E02 CHECK BEARING POINT 2) RETR FIT HOLDOWN STRAP ON FRONT END OF HOUSE (WEST) |
|
| 02/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE CONCERSION CHART FOR LSL HEADERS 2) DBL GIRDING MISSING DBL STUDS 3) SHEAR NOT NAILED TO TOP PLATE 4) CLIPS MISSING NAILS 5) RETRO FIT HOLDOWN L/S OF GARAGE 6) SHEAR TRANSFER MISSING TOP PLATE 7) STOPPED INSPECTION |