Permit: T05CM06221

Parcel: 106062280


Addresses:

916 W SIMMONS ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/19/2006 BUILDING - FINAL Approved IVRS - Inspection :*
09/13/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REINSTALL WROUGHT IRON WINDOW EMERGENCY RELEASE BEDROOMS
2) INSTALL ANTI-SIPHON EXTERIOR HOSE BIBS
3) CONNECT DISHWASHER DRAIN HOSE AND ELEVATE
4) ISOLATE SEPERATE-NUETRALS AND GROUNDS AT SUB-PANEL
5) INSTALL STOOP REAR DOOR
6) 220 VOLT DRYER RECEPTACLE (ROMEX EXPOSED)
7) KITCHEN RECEPTACLES TO BE GFCI
8) GFCI'S INOPERABLE
9) INSTALL ALL KITCHEN CABINETS-COUNTER TOPS
10) LABEL ELECTRIC PANEL BOXES CIRCUITS SERVED
11) CANNOT USE PVC FOR WATER HEATER PTR LINE
12) CAULK BASE OF TOILET AT FLOOR
13) KITCHEN RECEPTACLES TO BE ON SEPERATE CIRCUIT
07/13/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*