Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM06218
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/25/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/15/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE CITY OF TUCSON PLUMBING PLAN CHECK STAMP ON PLAN 2. PROVIDE VACUUM BREAKERS ON ALL HOSE BIBS 3. PROVIDE ELONGATED BOWL AND OPEN FRONT SEAT FOR STOOL WITH FLUSH HANDLE TO WIDE SIDE OF RESTROOM 4. PROVIDE A FAUCET WITH MINIMUM 1" AIR GAP AT SERVICE SINK, FAUCET WITH HOSE THREADS ON END REQUIRES VACUUM BREAKER. |