Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM06216
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : 1. TRUSS MISSING BRACING 2. SD3 & SD4 TRUSSES NOT BEARING ON BEARING POINT AND SD2 3. SD2A TRUSSES MISSING HANGERS AT MID POINT 4. SD2 TRUSSES NOT BEARING AT MID-POINT 5. STOPPED INSP. TOO MANY ITEMS CLIP & ROOF INSPECTION NOT MADE. |
|