Inspection History: FRAMING

Permit Number - T05CM06215

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2006 FRAMING Approved IVRS - Inspection :*
07/14/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TECO NAILS CANNOT BE USED TO SECURE SIMPSON HARDWARE THRU OSB USE 8D NAILS
2) REMOVE NAILER ON SHEARWALL 9 TO INSPECT MPA1 NAILS
07/12/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) #9 SHEARWALL REQUIRES MPA1 CLIPS AT 8" ON CENTER
2) TECO NAILS CANNOT BE USED TO SECURE SIMPSON HARDWARE THRU OSB
3) NAIL PROTECT FAU 220 WIRES WITHIN 1 1/4" OF PLATE SURFACE AND BY PATIO DOOR