Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM06215
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
07/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TECO NAILS CANNOT BE USED TO SECURE SIMPSON HARDWARE THRU OSB USE 8D NAILS 2) REMOVE NAILER ON SHEARWALL 9 TO INSPECT MPA1 NAILS |
|
07/12/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) #9 SHEARWALL REQUIRES MPA1 CLIPS AT 8" ON CENTER 2) TECO NAILS CANNOT BE USED TO SECURE SIMPSON HARDWARE THRU OSB 3) NAIL PROTECT FAU 220 WIRES WITHIN 1 1/4" OF PLATE SURFACE AND BY PATIO DOOR |