Permit: T05CM06214

Parcel: 141092810


Addresses:

6596 E SPLENDID LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM06214

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/17/2006 FRAMING Approved IVRS - Inspection :*
08/09/2006 FRAMING Denied 1) DUCT WORK PLENIUM CANNOT BEAR ON WIRING
2) REMOVE LOWER 12" OF NETTING TO INSPECT ANCHOR BOLTS
3) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
08/07/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 2, 3, 4 AND 5 NOT COMPLIED WITH
2) ITEM 4 AND 5 COVERED WITHOUT APPROVAL. REMOVE NET IN THOSE AREAS
07/14/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INTERIOR BEARING WALLS NOT CLIPPED OR ANCHORED PER PLAN
2) REPLACE DAMAGED SHEAR PANEL BY RANGE HOOD
3) DUCTWORK PLENIUM CANNOT BEAR ON WIRING
4) 3/DT1 NOT COMPLIED WITH
5) ANCHOR BOLTS MISSING THROUGHOUT
6) PROVIDE CITY OF TUCSON APPROVED TRUSS REPAIR
06/23/2006 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) STUCCO WEEP SCREED MUST EXTEND 2" BELOW FINISHED FLOOR
2) PLANS CALL FOR GAS LINE TO BE INSTALLED-EITHER INSTALL GAS LINES OR HAVE PLAN AND INSPECTION CARD REVISED TO DELETE GAS LINES
3) FRAMING NAILS IN THIS HOUSE ARE REQUIRED TO BE 16D 3" X ? NAILS 10D HAVE BEEN USED. HAVE ENGINEER OF RECORD PROVIDE CITY OF TUCSON WITH RECOMMENDATION/APPROVAL
4) INTERIOR BEARING WALLS MUST BE ANCHORED PER PLAN
5) S02 TRUSS MID POINT BEARING NOT ON BEARING WALL
6) TWO S02A TRUSSES MISSING MID POINT HANGERS
7) NO TRUSS DRAWINGS ON SITE SEVERAL TRUSSES APPEAR TO BE INSTALLED BACKWARD
8) STOPPED INSPECTION-TOO MANY ITEMS