Inspection History: FRAMING
Permit Number - T05CM06214
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/09/2006 | FRAMING | Denied | 1) DUCT WORK PLENIUM CANNOT BEAR ON WIRING 2) REMOVE LOWER 12" OF NETTING TO INSPECT ANCHOR BOLTS 3) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
|
08/07/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2, 3, 4 AND 5 NOT COMPLIED WITH 2) ITEM 4 AND 5 COVERED WITHOUT APPROVAL. REMOVE NET IN THOSE AREAS |
|
07/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INTERIOR BEARING WALLS NOT CLIPPED OR ANCHORED PER PLAN 2) REPLACE DAMAGED SHEAR PANEL BY RANGE HOOD 3) DUCTWORK PLENIUM CANNOT BEAR ON WIRING 4) 3/DT1 NOT COMPLIED WITH 5) ANCHOR BOLTS MISSING THROUGHOUT 6) PROVIDE CITY OF TUCSON APPROVED TRUSS REPAIR |
|
06/23/2006 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) STUCCO WEEP SCREED MUST EXTEND 2" BELOW FINISHED FLOOR 2) PLANS CALL FOR GAS LINE TO BE INSTALLED-EITHER INSTALL GAS LINES OR HAVE PLAN AND INSPECTION CARD REVISED TO DELETE GAS LINES 3) FRAMING NAILS IN THIS HOUSE ARE REQUIRED TO BE 16D 3" X ? NAILS 10D HAVE BEEN USED. HAVE ENGINEER OF RECORD PROVIDE CITY OF TUCSON WITH RECOMMENDATION/APPROVAL 4) INTERIOR BEARING WALLS MUST BE ANCHORED PER PLAN 5) S02 TRUSS MID POINT BEARING NOT ON BEARING WALL 6) TWO S02A TRUSSES MISSING MID POINT HANGERS 7) NO TRUSS DRAWINGS ON SITE SEVERAL TRUSSES APPEAR TO BE INSTALLED BACKWARD 8) STOPPED INSPECTION-TOO MANY ITEMS |