Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM06213
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 PT BEARING TRUSSES NOT BEARING AT MID POINT 2) TRUSS BRACING MISSING TRUSSES C02BV 3) #9 SHEARWALLS REQUIRE NAILING AT 3" ON CENTER AT EDGES 4) SHEARWALL CHANNELS NOT NAILED PER 5/SD2 5) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACES-USE FHA STRAPS 6) #8 SHEARWALLS REQUIRE EDGE NAILING AT 4" ON CENTER AND STUDS WITH HOLDOWNS REQUIRE NAILING 7) DIAGONAL WIND BRACES REQUIRE 2-16D NAILS AT ENDS 8) 8/SD3 NOT NAILED THRU ROOF 9) PLAN SD2 REQUIRES ROOFS TO BE NAILED NOT STAPLED |