Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM06210
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COL V TRUSSES NOT MID-POINT BEARING. 2. DIAGONAL BRACES REQUIRE 2-16d NAILS EACH END. 3. OVER SPAN STUD MISSING EAST WALL. 4. SHEAR WALL 9 REQUIRES 3" EDGE NAILING. 5. SHEAR WALL 8 REQUIRES 4" EDGE NAILING. |