Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ELECTRIC BOXES NOT INSTALLED 2. WIRES MUST TERMINATE IN BOX 3. SECURE WIRES WITHIN 8" OF BOXES 4. ANCHOR ENTRY SILL PLATES |
|
| 06/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STUCCO LATH NOT STAPLED AT 6" OC MANY LOCATIONS. 2. RED HEAD ANCHOR BOLTS LOOSE 3. WIRES MUST TERMINATE IN APPROVED BOXES. 4. ANCHOR WALLS. 5. ELECTRIC BOXES NOT INSTALLED. 6. WIRES OUT OF WALLS. 7. ANCHOR ENTRY PLATES. 8. WIRE SHEATING MUST EXTEND 1/4" IN BOXES. 9. BLOCK DUCT BOOTS 3 SIDES. 10. A01A TRUSSES NOT MID-POINT BEARING 11. FIRE STOP KITCHEN CHASE COLUMN 12. GARAGE SHEAR WALL NOT NAILS. |