Permit: T05CM06178

Parcel: 141091870

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/23/2006 BUILDING - FINAL Approved IVRS - Inspection :*
08/18/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LABEL ALL CIRCUITS IN ELECTRIC PANEL
2) ELECTRIC DEAD FRONT REQUIRES MOUNTING SCREWS
3) PANEL RISER HAS LOOSE/MISSING MOUNT SCREWS
4) NO POST TENSION TAG ON MAIN WATER VALVE
5) LEVEL A/C CONDENSOR
6) A/C CONDENSOR BLOCKS ACCESS TO DISCONNECT. MUST HAVE 30" X 30" UNOBSTRUCTED WORK AREA
7) CONDENSATE CANNOT DRAIN ON STOOP/WALKWAY
8) SECURE FAU WHIP
9) MARK FAU HEAT STRIP
10) NO POWER BATH GFCI CIRCUITS STRIP LABEL