Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM06177
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/23/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/21/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 3 AND 6 FROM 8/17/06 NOT DONE 2) WIRING NOT IN AT NEW CORNER L/R 3) WIRING NOT COMPLETE AT KITCHEN |
|
08/17/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RED HEAD ANCHOR BOLTS LOOSE 2) POST TENSION SLAB HAS 16" HOLE-PROVIDE APPROVED ENGINEERING 3) GALVANIZED DRYER DUCT CANNOT BE IN CONTACT WITH COPPER 4) OVER BORED BEARING STUDS AT N.W. CORNER BY PATIO DOOR. ADD STUD SHOE OR REPLACE STUDS (ELECTRIC) 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD PLATE SURFACES 6) ELECTRIC OUTLET REQUIRED AT KITCHEN PONY WALL 7) 3 STUDS OVER BORED AT KITCHEN SINK. ADD STUD SHOE OR REPLACE STUDS (PLUMBING) |