Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06177

Parcel: 141091860

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM06177

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/07/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection
Non overlapping dbl top plates not stamped (3 repeats)
No ladder access to roof
Refee
06/30/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/27/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER PLAN AND CHAPTER 23 OF IBC BASIC FRAMING CORRECTIONS ARE TO BE WITH 16D NAILS TOP AND BOTTOM PLATES HAVE BEEN FACE NAILED WITH 10D 3" X .131 NAILS. RE-NAIL HOUSE PER CODE OR HAVE ENGINEER OF RECORD PROVIDE APPROVED CITY OF TUCSON REPAIR
2) STRAP NON OVERLAPPING DBL TOP PLATE
3) BLOCK UNSUPPORTED EDGES OSB ON ROOF
4) ROOF NOT NAILED PER PLAN