Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM06177
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Non overlapping dbl top plates not stamped (3 repeats) No ladder access to roof Refee |
|
06/30/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER PLAN AND CHAPTER 23 OF IBC BASIC FRAMING CORRECTIONS ARE TO BE WITH 16D NAILS TOP AND BOTTOM PLATES HAVE BEEN FACE NAILED WITH 10D 3" X .131 NAILS. RE-NAIL HOUSE PER CODE OR HAVE ENGINEER OF RECORD PROVIDE APPROVED CITY OF TUCSON REPAIR 2) STRAP NON OVERLAPPING DBL TOP PLATE 3) BLOCK UNSUPPORTED EDGES OSB ON ROOF 4) ROOF NOT NAILED PER PLAN |