Permit: T05CM06176

Parcel: 141091850

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM06176

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/25/2006 FRAMING Approved IVRS - Inspection :*
08/14/2006 FRAMING Partial Approval IVRS - Inspection :*
HAVE TRUSS REPAIR APPROVED BY CITY OF TUCSON
08/11/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER APPROVED TRUSS DRAWINGS TRIPPLE R10 TRUSS WHICH IS DAMAGED MUST BE REPLACED
08/10/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1 AND 2 FROM 8/4/06 NOT DONE
08/04/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
2) TRIPPLE TRUSS AT GARAGE SHEAR WALL DAMAGED 4 PLACES BY DRILL. PROVIDE CITY OF TUCSON APPROVED REPAIR
3) NO ATTIC ACCESS
4) BLOCK OUT BOOTS 3 SIDES
5) INTERIOR NON BEARING WALLS MUST BE 1/2" FROM SCISSOR TRUSSES