Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM06176
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/14/2006 | FRAMING | Partial Approval | IVRS - Inspection :* HAVE TRUSS REPAIR APPROVED BY CITY OF TUCSON |
|
08/11/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER APPROVED TRUSS DRAWINGS TRIPPLE R10 TRUSS WHICH IS DAMAGED MUST BE REPLACED |
|
08/10/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 1 AND 2 FROM 8/4/06 NOT DONE |
|
08/04/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 2) TRIPPLE TRUSS AT GARAGE SHEAR WALL DAMAGED 4 PLACES BY DRILL. PROVIDE CITY OF TUCSON APPROVED REPAIR 3) NO ATTIC ACCESS 4) BLOCK OUT BOOTS 3 SIDES 5) INTERIOR NON BEARING WALLS MUST BE 1/2" FROM SCISSOR TRUSSES |