Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06165

Parcel: 13109066B


Addresses:

5843 E 24TH ST #01


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM06165

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/20/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
08/24/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. VACUUM BREAKERS TO HAVE TAMPER SCREWS BROKEN OFF
2. WATER HEATER VENTING TO BE COMPLETE
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING TO HAVE MINIMUM FALL (NO BACK PITCH)
4. EXTERIOR CLEANOUTS TO BE TO GRADE AND PLUGS TO BE MADE GAS TIGHT.