Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - CABLE DROP
Permit Number - T05CM06157
Inspection Description - ELECTRIC - CABLE DROP
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2006 | ELECTRIC - CABLE DROP | Approved | IVRS - Inspection :* | |
07/11/2006 | ELECTRIC - CABLE DROP | Denied | NO PLANS OR PERMIT ON SITE |