Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM06146

Parcel: 108240930


Addresses:

2482 E RIVER RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
05/25/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
05/23/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12' LIFT FRONT ENTRY
05/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8' LIFT COLUMNS
05/19/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT EAST WALL
05/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH WALL; LINTELS; NE CORNER TO 17'4"
05/17/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
05/16/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NO ONE @ JOBSITE
05/15/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
05/12/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT ON COLUMNS
05/11/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/10/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
8 FT. LIFT NORTH END
05/09/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NOT READY FOR INSPECTION
05/08/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SE, SW & W CORNERS @ GABLES 12'8"-16'8"
05/04/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12'8" ON SOUTH WALL AND EAST & WEST WINGS.
05/03/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT OK
05/02/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
NOT READY FOR INSPECTION.
04/28/2006 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
COULD NOT LOCATE PLANS @ SITE.