Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM06127
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2006 | FRAMING | Approved | IVRS - Inspection :* | |
08/01/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NAIL PROTECT WIRES WITHIN 1 1/4" OF PLATE/STUD SURFACE 2. FIRE STOP CHASE AT ENTRY 3. REMOVE WIRES FROM TRUSS GANG NAILS 4. GAS LINE NOT INSTALLED |
|
07/20/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BANG PLATE ON ELECTRIC GARAGE SHEAR AND THROUGHOUT 2) H2.5'S MISSING NAILS THROUGHOUT 3) SEAL PENETRATION ON VAPOR BARRIER OVER TUB NORTH WALL 4) MOVE PEX AWAY FROM CAN LIGHTS AND WIRES 5) DRYER VENT BROKEN IN CEILING 6) MISSING STAPLES ON MESH AT FRONT PORCH TOP 7) NORTH SIDE GABLE NOT LATHED 8) NO WATER PRESSURE 9) NO DWV TEST |