Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06127

Parcel: 141091820

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM06127

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BACK PORCH SHEARWALL TRANSFER NOT PER DETAIL 17/D1
06/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE KING STUDS NOT CLIPPED
2) GARAGE HEADER NOT BEARING ON TRIMMERS
3) R1B MISSING TRUSS BRACES
4) R1S MISSING TRUSS BRACES
5) 17/D1 NOT COMPLIED WITH AT SHEARWALL 5
6) NO LADDER ACCESS
06/09/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
CLIPS MISSING EVERYWHERE - ADVISE NOT COMPLETE ENOUGH TO INSPECT.