Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T05CM06127

Parcel: 141091820

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/21/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BACK PORCH SHEARWALL TRANSFER NOT PER DETAIL 17/D1
06/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GARAGE KING STUDS NOT CLIPPED
2) GARAGE HEADER NOT BEARING ON TRIMMERS
3) R1B MISSING TRUSS BRACES
4) R1S MISSING TRUSS BRACES
5) 17/D1 NOT COMPLIED WITH AT SHEARWALL 5
6) NO LADDER ACCESS
06/09/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
CLIPS MISSING EVERYWHERE - ADVISE NOT COMPLETE ENOUGH TO INSPECT.