Permit: T05CM06121

Parcel: 124041020

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/08/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/05/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. NEED BUSHINGS FOR #4 AND LARGER WIRE.
2. DON'T USE STRANDED UNDERGROUND NUT.
3. INSTALL 30 AMP. BREAKER FOR #10 WIRE.
4. COMPLETE ALL WIRING.
5. PROVIDE EARTH GROUND TO ALARM PANEL.
6. PAY RE-INSPECTION FEE PRIOR TO FINAL APPROVAL.
7. PROVIDE APPROVED PLAN FOR EMERGENCY LIGHTING.
06/02/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
FINISH WIRING, 30 AMP. MAX FOR INSTA-HOT, EXIT SIGN IDENTIFY EQUIPMENT. CHECK EMERGENCY LIGHTING.
06/01/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
CALL WHEN COMPLETE.
05/24/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
WORK NOT COMPLETE