Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED H20 PRESSURE |
|
| 07/20/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED DWV AND H20 2) SUPPORT VENT 90 DEGREE IN MASTER |
|
| 06/22/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA GAS MAIN RISER 2) PROTECT PEX FROM GUSSETT INSIDE GARAGE MAN DOOR AND MOVE FROM CAN LIGHTS 3) REPLACE CRUSHED STOVE DUCT 4) SHIM LOWER STRINGER TIGHT TO HEADER AND BLOCK AT MIDDLE UPPER STRINGER 5) H2.5 FLOOR TRUSSES AT MID-POINT 6) FHA POWDER 3" ABS 7) NEED 2ND A.B. AT WEST POWDER 8) H2.5 TRUSSES SOUTH OF STAIRS 9) FHA H20 MAIN 10) NEED CAULKING 11) STOPPED INSPECTION AFTER 1ST FLOOR |