Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/19/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGE OK PARTIAL APP. SHOWER DRAIN NOT APPROVED TILE LINED SHOWER PAN REQUIRES A FLANGED DRAIN W/CLAMP RING AND WEEP HOLES. A WATER TEST IS REQUIRED ON LINER BEFORE TILE IS SET. |
|
| 04/12/2006 | PLUMBING - INTERMEDIATE | Partial Approval | 1) CHECK VALVE FOR FINISHED WALL DIMENSION 2) ISOLATE AND SECURE PIPING 3) WIPE EXCESS FLUX FROM SOLDER JOINTS 4) INSULATE HOT 5) OK TO COVER AFTER COMPLETING 6) CLOSET FLANGE NOT SECURED 7) FDA DRAIN NOT SET |
|
| 04/05/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SHOWER VALVE AND DRAIN NOT YET INSTALLED CLOSET FLANGES SHALL BE SECURED TO FLOOR W/CORROSION RESISTANT FASTENERS. OK TO COVER EXCEPT AT SHOWER VALVE ABOVE CEILING PIPING OK TO COVER. |