Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/19/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/15/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEDIMENT TRAP AT WATER HTR 2) MARK HEAT STRIP ON HEAT PUMPS 3) ANTI-TIP ON RANGE 4) SERVICE OUTLET REQUIRED WITHIN 25' OF HEAT PUMP 5) COMPLETE COUNTER TOPS 6) REMOVE GAS WHIP AT DRYER |
|
| 03/09/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SET SCREW AT VACUUM BREAKERS 2) COVERS ON UNUSED BOXES 3) WATER BOND LABEL IN PANEL 4) NEUTRALS DBL LUGGED 5) SMOKIE CIRCUIT ARC FAULT 6) SEDIEMENT TRAP REQUIRED AT ON DEMAND WATER HTR 7) TERMINATE T & P LINE 6" FROM GROUND 8) DISCONNECT REQUIRED AT WATER HTR 9) XMAS OUTLET NEEDS BUBBLE COVER 10) INSTALL FLOOD LIGHTS 11) STOPPED INSPECTION |