Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - UFER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2010 | ELECTRIC - UFER | Approved | IVRS - Inspection :* | |
| 11/16/2009 | ELECTRIC - UFER | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY OWNER |
|
| 11/12/2009 | ELECTRIC - UFER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PANEL NOT GROUNDED REQUIRES GROUND ROD SYSTEM 2) MIXED BREAKERS IN PANEL MUST BE SQUARE D TO METER PANEL/CAP CONDUCTOR ENDS/BOND GAS AND WATER 3) SECURE BOXES KITCHEN RANGE AND OUTLET MASONRY WALL INSTALL PER CODE 4) INSTALL #6 WIRE RANGE PER PLAN 5) NAIL PROTECT ROMEX THROUGHOUT 6) SECURE HOME RUNS 7) CHANNEL 1 1/4" ROMEX IN MASONRY BEDROOM 2 EAST WALL 8) INSTALL SMOKE ALARM PER CODE WEST SIDE BEDROOM 2 DOOR 9) SECURE METAL BOX MASTER WEST WALL/ROMEX CONNECTORS 10) CEILING FAN BOXES THROUGHOUT 11) PROVIDE ROMEX CONNECTORS METAL BOXES AND GROUND METAL BOXES 12) MISSING CIRCUITS TO FURNACE, WATER HEATER AND COOLER |
|
| 08/25/2009 | ELECTRIC - UFER | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE GROUND ROD SYSTEM 2) OK TO GROUT KITCHEN WEST WALL TOP OUT 3) EXPOSE FOOTERS FRONT PORCH PER PLAN 4) PLAN CALLS FOR CONTINOUS FOOTER 3/3 MID BEARING WALL 5) EXPOSE FOOTER M REAR COLUMNS 6) NOT PLUMBED PER PLAN, EXPOSE PLUMBING ROUGH SOIL. PROVIDE TESTS NEW PLUMBING. PLUMBING NOT VENTED. SUPPLY LINES NOT PER PLAN OR CODE 7) MISSING EXT. LIGHTS AND OUTLETS PER PLAN 8) TERMINATE ALL ROMEX IN APPROVED BOXES. SECURE 8' FROM BOXES 9) INSTALL CEILING FAN BOXES PER PLAN 10) ELECTRICAL WORK MUST MATCH APPROVED PLAN OR REVISE, WORK NOT COMPLETE ENOUGH TO INSPECT 11) STOPPED INSPECTION |
|
| 07/30/2009 | ELECTRIC - UFER | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 06/28/2006 | ELECTRIC - UFER | Denied | IVRS - Inspection : See detailed listing on site.| 999* |