Inspection History: FRAMING

Date Description Inspector Results Comments
05/11/2006 FRAMING Approved IVRS - Inspection :*
05/09/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H2.5 FLOOR TRUSSES AT MID BEARING
2) BANG CONDENSATE LINE AND FRIDGE LINE
3) SHIM STRINGERS HEADERS
4) SHIM STAIR PLATFORM
5) MOVE PEX OFF METAL GUSSET
6) RE-INSTALL POWDER VENT FAN
7) FIRE BLOCK S.W. BED CHASE AND TRUNK CHASE