Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM06003

Parcel: 12306022G


Addresses:

2200 E ELM ST


Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T05CM06003

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/27/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
08/28/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1. GAS AT MECH. RM. #600 -- GAS FOR #600, #700, #800, #900 AND 1 1/2" STUB IN AT #100 OK
2. ABS DWV AT #700, #800 & #900 OK THRU ROOF
3. COPPER AT #700, #800 & #900 OK
HOT INSULATION OK
4. CLOSET FLANGES AND TUBS #700, #800, #900 OK
06/02/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
OK TO COVER UNDERGROUND OK PRESSURE TEST.
05/30/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1. REQUIRE SCOTCH COAT UNDER GRADE - CONTRACTOR TO CLEAN ROCK AND CALICHI FROM TRENCH BEFORE BACKFILLING
05/09/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
2 1/2 SCOTCH KOTE FROM EXISTING 3" PLUG VALVE
170' TO EXISTING 2" WITH 14 PSI PRESSURE TEST.
PROVIDE CONTINUOUS SUPPORT UNDERPIPING
WRAP 3" TEE AND REDUCERS.