Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM05994
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* UPSTAIRS CLOSET FLANGES OK CALL IN 03075 FOR DOWNSTAIRS CLOSET FLANGES |
|
| 11/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRECTION MADE, SHALL SEE CLOSET FLANGES FOR APPROVAL. |
|
| 11/27/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF PARTIAL 1. SHALL PROVIDE REVISED PLAN FOR AIR ADMITTANCE VALVE AT WASHER BOX. 2. SHALL SUPPORT HORIZONTAL ABS AT 4' INTERVALS. 3. PROVIDE SEPARATION OF HOT & COLD PEX & SUPPORT TUB SHOWER VALVES & WATER HEATER PIPING CORRECTLY. 4. PROVIDE WATER HEATER T&P DRAIN - GRAVITY TO DAYLIGHT. 5. CLOSET FLANGES TO BE SECURED & BE 1/4" ABOVE FINISH FLOOR. |