Permit: T05CM05994

Parcel: 126211450

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM05994

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/20/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
UPSTAIRS CLOSET FLANGES OK
CALL IN 03075 FOR DOWNSTAIRS CLOSET FLANGES
11/30/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CORRECTION MADE, SHALL SEE CLOSET FLANGES FOR APPROVAL.
11/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF PARTIAL
1. SHALL PROVIDE REVISED PLAN FOR AIR ADMITTANCE VALVE AT WASHER BOX.
2. SHALL SUPPORT HORIZONTAL ABS AT 4' INTERVALS.
3. PROVIDE SEPARATION OF HOT & COLD PEX & SUPPORT TUB SHOWER VALVES & WATER HEATER PIPING CORRECTLY.
4. PROVIDE WATER HEATER T&P DRAIN - GRAVITY TO DAYLIGHT.
5. CLOSET FLANGES TO BE SECURED & BE 1/4" ABOVE FINISH FLOOR.