Permit: T05CM05993

Parcel: 126211460

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM05993

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/20/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
UPSTAIRS CLOSET FLANGES OK
CALL 03075 FOR DOWNSTAIRS FLANGE
11/30/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CORRECTION MADE. SHALL SEE CLOSET FLANGE CORRECT INSTALL FOR APPROVAL
11/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF PARTIAL
1. SHALL SUPPORT OVERHEAD ABS T 4' INTERVALS ON HORIZONTAL.
2. PROVIDE SEPARATION OF HOT & COLD TUBING, SUPPORT TUB & SHOWER VALVES CORRECTLY & WATER HEATER STUB OUTS.
3. PROVIDE WATER HEATER GRAVITY DRAIN TO DAYLIGHT FOR T & P
4. CLOSET FLANGES TO BE SECURED 1/4" ABOVE FINISH FLOOR