Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM05993
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* UPSTAIRS CLOSET FLANGES OK CALL 03075 FOR DOWNSTAIRS FLANGE |
|
| 11/30/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRECTION MADE. SHALL SEE CLOSET FLANGE CORRECT INSTALL FOR APPROVAL |
|
| 11/27/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF PARTIAL 1. SHALL SUPPORT OVERHEAD ABS T 4' INTERVALS ON HORIZONTAL. 2. PROVIDE SEPARATION OF HOT & COLD TUBING, SUPPORT TUB & SHOWER VALVES CORRECTLY & WATER HEATER STUB OUTS. 3. PROVIDE WATER HEATER GRAVITY DRAIN TO DAYLIGHT FOR T & P 4. CLOSET FLANGES TO BE SECURED 1/4" ABOVE FINISH FLOOR |