Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T05CM05991
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/09/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NOTES 1. GROUND SERVICE DISCONNECT TO BE LOCATED OUTSIDE PLANS TO REFLECT, INSTALL PER CODE. 2. SMOKE DETECTORS MUST BE 3' MIN. FROM AC REGISTERS INSTALL PER PLANS. 3. FEEDERS FOR SUB-PANELS TO SMALL. 4. USE LISTED EXTENDER RINGS FOR BOXES MORE THAN 1/4" FROM FACE OF DRYWALL. |
|
| 10/20/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PLANS MUST BE PER FIELD INSTALLATION, SUB-PANELS, SIZE, FEEDERS, AND SERVICE ARRANGEMENT, GROUNDING |