Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T05CM05991

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2006 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/09/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
NOTES
1. GROUND SERVICE DISCONNECT TO BE LOCATED OUTSIDE
PLANS TO REFLECT, INSTALL PER CODE.
2. SMOKE DETECTORS MUST BE 3' MIN. FROM AC REGISTERS INSTALL PER PLANS.
3. FEEDERS FOR SUB-PANELS TO SMALL.
4. USE LISTED EXTENDER RINGS FOR BOXES MORE THAN 1/4" FROM FACE OF DRYWALL.
10/20/2006 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
PLANS MUST BE PER FIELD INSTALLATION, SUB-PANELS, SIZE, FEEDERS, AND SERVICE ARRANGEMENT, GROUNDING