Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2006 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 04/24/2006 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* CONTINUE W/TRACER WIRE FOR EACH LINE. OK TO COVER AFTER INSTALLING. PROVIDE HB VAC BREAKER. SCH 40 PVC INSTALLED PER PLAN. |
|
| 04/19/2006 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* BLUE TRACER WIRE REQUIRED, SECURE TO TUBE EVERY 8' INSTALL PER MANUFACTURER SPECIFICATIONS, SHADING, AND HAUNCHING IS REQUIRED REMOVE CHUNKS FROM AROUND PIPING, SHADE THOROUGHLY HAVE EXTRA CLEAN DIRT ABOVE TUBING AS REQUIRED BY SPECS. UPC REQUIRES 12" OF CLEAN FILL BEFORE BACKFILLING W/MECHANICAL EQUIPMENT. HB VACUUM BREAKERS REQUIRED TO BE INSTALLED BEFORE INSPECTION. |