Permit: T05CM05980

Parcel: 129131480


Addresses:

706 E 32ND ST #01

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
05/15/2006 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
04/24/2006 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
CONTINUE W/TRACER WIRE FOR EACH LINE. OK TO COVER
AFTER INSTALLING. PROVIDE HB VAC BREAKER.
SCH 40 PVC INSTALLED PER PLAN.
04/19/2006 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
BLUE TRACER WIRE REQUIRED, SECURE TO TUBE EVERY 8'
INSTALL PER MANUFACTURER SPECIFICATIONS, SHADING, AND HAUNCHING IS REQUIRED
REMOVE CHUNKS FROM AROUND PIPING, SHADE THOROUGHLY
HAVE EXTRA CLEAN DIRT ABOVE TUBING AS REQUIRED BY SPECS.
UPC REQUIRES 12" OF CLEAN FILL BEFORE BACKFILLING W/MECHANICAL EQUIPMENT.
HB VACUUM BREAKERS REQUIRED TO BE INSTALLED BEFORE INSPECTION.