Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM05973

Parcel: 141091160


Addresses:

6616 E WRIGLEY WY


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM05973

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/29/2006 FRAMING Approved IVRS - Inspection :*
06/14/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
06/07/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1 REPLACE SHEAR BLOCK AT ELECTRIC IN GARAGE
2) SHIM A8 TRUSS AT BEARING WALL
3) ADD STUDS PER PLAN UNDER SHORT GIRDER TRUSS IN GARAGE AND UNDER GIRDER IN DINING AREA
4) TIGHTEN RED HEADS WITH WRENCH
5) BLOCK REGISTER HALL BATH
6) STAPLE STOVE WIRE
7) NEED RECEPTACLE WEST OF FRONT DOOR
8) NO DWV WATER TEST
9) VENT RANGE HOOD TO OUTSIDE
10) REPAIR STUCCO WIRE MASTER TUB